Automated measurement of inter-arytenoid distance on 4D laryngeal CT: A validation study.

Ma Andrew, Desai Nandakishor, Lau Kenneth K, Palaniswami Marimuthu, O'Brien Terence J, Palaniswami Paari, Thyagarajan Dominic

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Changes to the voice are prevalent and occur early in Parkinson's disease. Correlates of these voice changes on four-dimensional laryngeal computed-tomography imaging, such as the inter-arytenoid distance, are promising biomarkers of the disease's presence and severity. However, manual measurement of the inter-arytenoid distance is a laborious process, limiting its feasibility in large-scale research and clinical settings. Automated methods of measurement provide a solution. Here, we present a machine-learning module which determines the inter-arytenoid distance in an automated manner. We obtained automated inter-arytenoid distance readings on imaging from participants with Parkinson's disease as well as healthy controls, and then validated these against manually derived estimates. On a modified Bland-Altman analysis, we found a mean bias of 1.52 mm (95% limits of agreement -1.7 to 4.7 mm) between the automated and manual techniques, which improves to a mean bias of 0.52 mm (95% limits of agreement -1.9 to 2.9 mm) when variability due to differences in slice selection between the automated and manual methods are removed. Our results demonstrate that estimates of the inter-arytenoid distance with our automated machine-learning module are accurate, and represents a promising tool to be utilized in future work studying the laryngeal changes in Parkinson's disease.

Для цитирования: Ma Andrew, Desai Nandakishor, Lau Kenneth K, Palaniswami Marimuthu, O'Brien Terence J, Palaniswami Paari, Thyagarajan Dominic. Automated measurement of inter-arytenoid distance on 4D laryngeal CT: A validation study.. PloS one. 2023. DOI: 10.1371/journal.pone.0279927.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.