MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1101/2025.04.03.25325101

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2025

Predictive performance of wearable sensors for mortality risk in older adults: a model development and validation study.

Harper Charlie, Sturge Adam D, Chan Shing, Maylor Ben, Shreves Alaina, Meier Daniel, Patkee Prachi, Schoonbee John, Strange Adam, Nabholz Christoph, Bennett Derrick, Doherty Aiden

СтатьяПрепринтПеревод в очереди

Аннотация

BACKGROUND

Many adults in high-income countries carry a device capable of measuring physical-activity behaviour. Thus, there is public health need to understand whether such data can enhance prediction of future health outcomes. We aimed to investigate whether device-measured daily-step count and walking cadence improve the prediction of mortality beyond traditional risk-factors.

METHODS

Risk models were developed to predict five-year all-cause mortality using data from the UK Biobank accelerometer sub-study, with external validation in the US 2011-2014 National Health and Nutrition Examination Survey (NHANES). Median daily-step count and peak one-minute walking cadence were derived using self-supervised machine learning models from seven-day wrist-worn accelerometer data. Cox models were used to develop a baseline model incorporating traditional risk-factors, and a baseline model plus accelerometer data (i.e. daily-steps and walking cadence). Changes in model performance were assessed using Harrell's C-index, net reclassification index (NRI; 10% threshold), and the Nam-D'Agostino calibration test.

FINDINGS: Among 79,717 UK Biobank participants, 1,640 died within 5-years. Adding accelerometer data to the baseline model modestly improved risk discrimination and classification with a change in c-index of 0.008 (95% confidence interval [CI] 0.005-0.011) and 3.3% NRI (95%CI 2.1%-4.5%). Greatest improvements in prediction were observed in participants with prior disease at baseline, showing a change in c-index of 0.028 (95%CI 0.019-0.039) and 5.9% NRI (95%CI 3.1%-8.6%). In the NHANES external validation cohort (n=4,713; deaths=378), similar improvements in prediction were observed (change in c-index: 0.015, 95%CI 0.007-0.025; NRI: 4.0%, 95%CI 0.7%-7.4%). All models were well calibrated (Nam-D'Agostino χ2 range: 6.8-13.2).

INTERPRETATION: Device-measured daily-step count and walking cadence consistently demonstrated modest improvements in predicting mortality risk beyond traditional risk-factors, with the most significant enhancements seen in individuals with prior disease. These findings suggest that incorporating information from wearables does provide important new ways to improve risk stratification for targeted intervention in high-risk individuals.

Для цитирования: Harper Charlie, Sturge Adam D, Chan Shing, Maylor Ben, Shreves Alaina, Meier Daniel, Patkee Prachi, Schoonbee John, Strange Adam, Nabholz Christoph, Bennett Derrick, Doherty Aiden. Predictive performance of wearable sensors for mortality risk in older adults: a model development and validation study.. medRxiv : the preprint server for health sciences. 2025. DOI: 10.1101/2025.04.03.25325101.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.