MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2023.106076

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2023

Static compression and fatigue behavior of heat-treated selective laser melted titanium alloy (Ti6Al4V) gyroid cylinders.

Hitchon Sydney, Anderson William, Milner Jaques S, Hong Gregory, Ivanov Todor, Willing Ryan, Holdsworth David

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Porous additively-manufactured structures could have a niche in orthopaedic implants, due to their potential to reduce stiffness (stress-shielding), improve bony ingrowth, and potential to house reservoirs of drug-eluting non-structural biomaterials. Computer aided design and finite element (FE) modelling plays an important role in the design of porous structured biomedical implants; however it is important to validate both their static and fatigue behaviours using experimental testing. This study compared the mechanical behaviors of titanium cylindrical gyroid structures of varying porosities using physical testing of additively manufactured prototypes and FE models. There was agreement in the measured and predicted relationships between porosity and apparent modulus of elasticity. As porosity increased (and wall thickness decreased), the structures failed at a lower number of cycles when loaded at the same percentage of their yield strengths. Calibration of the fatigue strength coefficient from a previously published value of 1586.5 MPa-1225 MPa greatly improved the fatigue life prediction accuracy for all the gyroid structures. Nevertheless, differences of up to 54% in the predicted versus experimental fatigue lives remained, which could be attributed to difficulties with how the precise time and location of failure is defined in the simulations, and/or minor differences in nominal and actual porosities. Although further calibration and validation should be explored, this study demonstrates that static and fatigue FE-modelling techniques could be used to aid in the design of porous prosthetics.

Для цитирования: Hitchon Sydney, Anderson William, Milner Jaques S, Hong Gregory, Ivanov Todor, Willing Ryan, Holdsworth David. Static compression and fatigue behavior of heat-treated selective laser melted titanium alloy (Ti6Al4V) gyroid cylinders.. Journal of the mechanical behavior of biomedical materials. 2023. DOI: 10.1016/j.jmbbm.2023.106076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.