MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2019.11.015

Медицинская библиотека · The Journal of arthroplasty · 2019

Outcomes of Isolated Head and Liner Exchange Using Large Femoral Heads and Modern Liners in Revision Total Hip Arthroplasty.

Sutter E Grant, Akram Faisal, Miller Adam, Paprosky Wayne G, Berger Richard A, Gerlinger Tad L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability after these surgeries. Most reports have studied constructs using ≤28 mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange.

METHODS

We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32 (23%), 36 (62%), or 40 (15%) mm diameter heads. Cross-linked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow-up was 3.5 (1.0-9.1) years. Statistical analyses were performed with significance set at P < .05.

RESULTS

Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. After revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes.

CONCLUSION

Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical, or implant factors that reduced the risk of instability or other complication.

Для цитирования: Sutter E Grant, Akram Faisal, Miller Adam, Paprosky Wayne G, Berger Richard A, Gerlinger Tad L. Outcomes of Isolated Head and Liner Exchange Using Large Femoral Heads and Modern Liners in Revision Total Hip Arthroplasty.. The Journal of arthroplasty. 2019. DOI: 10.1016/j.arth.2019.11.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.