DOI 10.1016/j.semarthrit.2021.05.014
The OMERACT Knee Inflammation MRI Scoring System: Validation of quantitative methodologies and tri-compartmental overlays in osteoarthritis.
Аннотация
OBJECTIVE
To validate a revised version of the KIMRISS method for quantification of BML and synovitis-effusion in the knee by comparison with an established method, MOAKS.
METHODS
Novel calibration tools were developed for both methods. We compared reliability for status and change scores of BML and synovitis-effusion on baseline and one-year MRI scans.
RESULTS
Significant increase in both BML and synovitis-effusion was evident using KIMRISS but only for synovitis-effusion using MOAKS. Pre-specified targets for acceptable reliability (≥0.80 and ≥0.70 for status and change scores, respectively) were achieved more frequently for KIMRISS for both BML and synovitis.
CONCLUSION
Per OFISA criteria, KIMRISS should progress to assessment of discrimination.