BACKGROUND
Non-unions after intramedullary nailing of femoral shaft fractures are a significant problem. Treatment options such as augmenting with plates or exchange nailing have been proposed. The ideal treatment remains controversial.
METHODS
Augmentative plating using a 4.5 mm LCP or a 3.2 mm LCP leaving the nail in situ was tested biomechanically and compared to exchange intramedullary nailing in a SawboneTM model of a femoral shaft non-union.
RESULTS
The difference of fracture gap motion in axial testing was small. In rotational testing, the exchange nail allowed for the largest amount of motion. The 4.5 mm augmentative plate was the most stable construct in all loading conditions.
CONCLUSIONS
Augmentative plating using a 4.5 mm LCP plate while leaving the nail in situ is biomechanically superior to exchange intramedullary nailing. A small fragment 3.2 mm LCP is undersized and does not reduce fracture motion sufficiently in a femoral shaft non-union.