DOI 10.1016/j.jhsa.2023.06.022

Медицинская библиотека · The Journal of hand surgery · 2023

Do Intramedullary Screws Provide Adequate Fixation for Humeral and Ulnar Components in Total Elbow Arthroplasty? A Cadaveric Analysis.

Nazzal Ehab M, Mattar Luke T, Newell Benjamin W, Coutinho Dominic V, Kaufmann Robert A, Baratz Mark E, Debski Richard E

СтатьяПеревод в очереди

Аннотация

PURPOSE: The objective of this study was to determine the structural properties of the cadaver bone-screw interface for cementless intramedullary screw fixation in the context of total elbow arthroplasty.

METHODS

The intramedullary canals of seven humerus and seven ulna specimens from fresh-frozen cadavers were drilled using custom drill bits until the inner cortex was reached and then hand tapped for the corresponding thread size. Titanium screws were advanced into the tapped holes until securely seated. The bones were potted and then mounted on a uniaxial material testing machine. A tensile load was applied, and end-of-test elongation, failure load, energy absorbed, and stiffness were determined. End-of-test load and elongation were defined as the elongation and load experienced by the structure at 3,000 N or failure. Each specimen was inspected for evidence of pullout, loosening, or visible fractures.

RESULTS

The end-of-test load and elongation for the humerus specimens were 2721 ± 738 N and 3.0 ± 0.9 mm, respectively. The ulna specimens reached 92% of the humerus specimens' end-of-test load at 2,514 ± 678 N and 120% of their end-of-test elongation (3.6 ± 0.6 mm). The stiffness of the humerus specimens was 1,077 ± 336 N/mm, which was 1.3 times greater than the stiffness of the ulna specimens (790 ± 211 N/mm). Lastly, the energy absorbed by the humerus samples was 3.6 ± 1.6 J, which was 92% of the energy absorbed by the ulna samples at 3.9 ± 1.1 J. One humerus and three ulnas failed before the end-of-test load of 3,000 N. Two failures were caused by screw pullout and two by bone fracture.

CONCLUSIONS

Our findings demonstrate that intramedullary screw fixation is successful in withstanding forces that are greater than required for osseointegration.

CLINICAL RELEVANCE: Uncemented fixation may be beneficial in elbow arthroplasty.

Для цитирования: Nazzal Ehab M, Mattar Luke T, Newell Benjamin W, Coutinho Dominic V, Kaufmann Robert A, Baratz Mark E, Debski Richard E. Do Intramedullary Screws Provide Adequate Fixation for Humeral and Ulnar Components in Total Elbow Arthroplasty? A Cadaveric Analysis.. The Journal of hand surgery. 2023. DOI: 10.1016/j.jhsa.2023.06.022.