MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bsd.0000000000000210

Медицинская библиотека · Journal of spinal disorders & techniques · 2015

Radiation exposure to surgeon in minimally invasive transforaminal lumbar interbody fusion with novel spinal locators.

Fan Guoxin, Fu Qingsong, Gu Guangfei, Zhang Hailong, Guan Xiaofei, Zhang Lei, Gu Xin, He Shisheng

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

A prospective study.

OBJECTIVE

To further investigate the implication of our surface locator and intradermal locator to reduce the radiation exposure to surgeons in minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) surgery.

SUMMARY OF BACKGROUND DATA: Our previous studies published in the journal have introduced our novel spinal locators effectively minimizing fluoroscopic time during minimally invasive spinal surgery.

METHODS

Twenty patients underwent MIS-TLIF surgery with G-arm fluoroscopy from January 2013 to June 2013. There were 10 patients in group A who underwent standard MIS-TLIF using our spinal locators, and the other 10 in group B underwent conventional MIS-TLIF without spinal locators. The radiation dosages to the arm, the finger, the whole body, thyroid gland, gonad gland, and the eye of the surgeon were measured by thermoluminescence badges for both groups.

RESULTS

All 20 patients (9 male, 11 female), aged from 48 to 77 years old, successfully underwent the surgery. The operation time was 171.20±10.28 minutes for group A and 189.80±11.99 minutes for group B. The fluoroscopy time was 49.60±7.32 seconds for group A and 68.40±7.62 seconds for group B, hence a reduction of 27.49% was observed. There was no correlation between operation time and exposure time for group A or group B. The radiation reduction was 35.28% for the arm, 17.95% for the finger, 45.23% for the whole body, 53.62% for the thyroid gland (protected), 52.44% for the thyroid gland (unprotected), 44% for gonad gland (protected), 36.42% for the gonad gland (unprotected), 59.42% for the eye (protected), and 59.70% for the eye (unprotected).

CONCLUSION

The study indicated that radiation exposure to the surgeon would be effectively reduced in MIS-TLIF using our surface locator and intradermal locator, and it could be another practical choice for radiation-minimizing strategy.

Для цитирования: Fan Guoxin, Fu Qingsong, Gu Guangfei, Zhang Hailong, Guan Xiaofei, Zhang Lei, Gu Xin, He Shisheng. Radiation exposure to surgeon in minimally invasive transforaminal lumbar interbody fusion with novel spinal locators.. Journal of spinal disorders & techniques. 2015. DOI: 10.1097/bsd.0000000000000210.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.