MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0248-8663(86)80127-8

Медицинская библиотека · La Revue de medecine interne · 1986

[Inhibitors of factor VIII in non-hemophilic patients. Biological and therapeutic aspects. Apropos of 3 cases].

Jude B, Goudemand J, Jouet J P, Watel A, Caron C, Rouget J P, Bauters F, Cosson A

Клинический случайАннотация на английскомСтатьяПеревод в очереди

Аннотация

A coagulation inhibitor of the anti-factor VIII: C type was detected in three non-haemophilic male patients aged 75, 70 and 52 respectively. In all three patients antibody titres were low (less than 12.5 Bethesda units initially, less than 20 units subsequently), and a low but detectable level of factor VIII: C persisted (7 to 12 p. 100 in two patients who had severe haemorrhages and 2.100 in the third one). The 3 inhibitors inactivated factor VIII: C with a complex, type II kinetics (Biggs et al.). Strong doses of anti-haemophilic A fractions were biologically effective in one patient but could not stop severe bleeding. Activated plasma fractions were used successfully on several occasions. Once, moderate and repeated doses of anti-haemophilic A fractions resulted in satisfactory correction of factor VIII: C level, and a minor surgical operation could be performed. An immunosuppressive treatment was administered for 3 weeks to one patient and for 3 months to the other two patients. In all three cases the inhibitor disappeared after 5 to 8 months. In non-haemophilic patients with factor VII: C inhibitor the treatment of haemorrhagic episodes must take into account the severity of bleeding, then the usually complex kinetics of the inhibitor; thus it cannot be a direct copy of the treatment used in haemophiliacs with type I inhibitors.

Для цитирования: Jude B, Goudemand J, Jouet J P, Watel A, Caron C, Rouget J P, Bauters F, Cosson A. [Inhibitors of factor VIII in non-hemophilic patients. Biological and therapeutic aspects. Apropos of 3 cases].. La Revue de medecine interne. 1986. DOI: 10.1016/s0248-8663(86)80127-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.