DOI 10.1016/j.spinee.2023.01.019
The use of MRI, PET/CT, and nuclear scintigraphy in the imaging of pyogenic native vertebral osteomyelitis: a systematic review and meta-analysis.
Аннотация
BACKGROUND CONTEXT: Native vertebral osteomyelitis (NVO) is a severe infection with an increasing incidence globally. Although there is no widely agreed upon reference standard for diagnosis of the disease, imaging plays a crucial role. Magnetic resonance imaging (MRI) is currently the imaging modality of choice. In recent years, advances in imaging have allowed for a larger role for alternative imaging techniques in the setting of NVO.
PURPOSE: Our aim was to evaluate the diagnostic accuracy of MRI, PET/CT, and nuclear imaging, namely 67Gallium and 99mTechnetium scintigraphy, in the diagnosis of pyogenic NVO.
STUDY DESIGN/
SETTING
We conducted a systematic review of five medical databases and included all studies from 1970 to September 2021 that compared imaging techniques and provided sufficient data for diagnostic test accuracy meta-analysis.
METHODS
Abstract screening, full text review, and data extraction were done by a pair of independent reviewers. Nonnative and nonpyogenic patients were excluded. A bivariate random effect model was used for meta-analysis.
RESULTS
Twenty studies were included in the meta-analysis, encompassing a total of 1,123 imaging studies. The meta-analysis sensitivity and specificity of MRI were 90% and 72% respectively; those of PET/CT were 93% and 80%; those of 67Ga were 95% and 88%; those of 99mTc were 86% and 39%; and the sensitivity and specificity of combined Ga and Tc were 91% and 92% respectively in the setting of suspected NVO.
CONCLUSIONS
67Ga has the highest sensitivity for NVO, and its specificity is augmented when combined with 99mTc. MRI and PET/CT are both highly sensitive modalities, although the specificity of PET/CT is slightly better. MRI remains an appropriate initial test depending on the availability of other modalities.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.