MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00365513.2018.1499957

Медицинская библиотека · Scandinavian journal of clinical and laboratory investigation · 2018

Comparison of second- and third-generation immunoassays for detection of anti-cyclic citrullinated peptide antibodies.

Ji Misuk, Hur Mina, Moon Hee-Won, Park Mikyoung, Yun Yeo-Min, Lee Sang-Heon

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

Anti-cyclic citrullinated peptide antibodies (anti-CCPs) are important diagnostic markers for rheumatoid arthritis (RA). We evaluated the analytical and clinical performance of the QUANTA Flash CCP3 (INOVA Diagnostics, USA), a fully automated third-generation anti-CCP assay, in comparison with three second-generation anti-CCP (CCP2) assays. A total of 300 sera (67 from RA patients, 64 from other rheumatic diseases, 43 from osteoarthritis [OA], and 126 from other conditions) were tested with QUANTA Flash CCP3, Kallestad Anti-CCP II (Bio-Rad, USA), Elecsys Anti-CCP (Roche Diagnostics GmbH, Germany), and ARCHITECT Anti-CCP (Abbott Diagnostics, USA). Within-run and total imprecision (% coefficient of variation) of the QUANTA Flash CCP3 were <6%, and its linearity was acceptable over the claimed range (4.0-2,749.7 chemiluminescent units). The frequency of anti-CCP was similar between QUANTA Flash CCP3 and the other CCP2 assays in the RA (67.2% vs. 62.7-70.1%), other rheumatic diseases (7.8% vs. 6.3%), and OA (2.3% vs. 0-2.3%) groups. The concordance rate between QUANTA Flash CCP3 and the other assays ranged from 96.3% to 97.7% (kappa from 0.87 to 0.92). For the diagnosis of RA, the sensitivity/specificity was 67.2%/95.7%, 62.7%/98.3%, 70.2%/96.6%, and 67.2%/97.9%, and the areas under the receiver operating characteristic curves were 0.851, 0.791, 0.853, and 0.867 for QUANTA Flash CCP3, Kallestad, Elecsys, and ARCHITECT assays, respectively. The performance of the QUANTA Flash CCP3 was satisfactory and comparable to that of the three CCP2 assays. This fully automated assay would be a practical and reasonable option in clinical laboratories.

Для цитирования: Ji Misuk, Hur Mina, Moon Hee-Won, Park Mikyoung, Yun Yeo-Min, Lee Sang-Heon. Comparison of second- and third-generation immunoassays for detection of anti-cyclic citrullinated peptide antibodies.. Scandinavian journal of clinical and laboratory investigation. 2018. DOI: 10.1080/00365513.2018.1499957.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.