Deployment of a real-time prostate cancer confirmation system with Raman spectroscopy: fine-tuning versus test-time adaptation of 1D CNNs.
Аннотация
SIGNIFICANCE: Prostate cancer (PCa) confirmation during needle-based procedures is limited by the lack of intraoperative diagnostic tools. Raman spectroscopy (RS), combined with classification models, offers a promising solution for real-time tissue characterization, potentially improving sampling accuracy and therapy guidance. However, such models require tissue- and organ-specific data, making deployment in studies challenging due to limited data availability.
AIM: The aim is to develop a one-dimensional convolutional neural network (1D-CNN) for real-time PCa detection using RS on prospectively collected ex vivo data, leveraging multi-organ pre-training and evaluating two domain adaptation strategies.
APPROACH: A ResNet-based 1D-CNN was trained for binary cancer/normal tissue classification. We implemented a pre-training strategy using retrospective RS data from brain, breast, and prostate (202 patients), along with pre-trained bacterial models, followed by efficient fine-tuning and test-time adaptation (TTA) to adapt to unseen domains.
RESULTS
Prospective RS data were acquired using a robotic system from 10 PCa patients (two to five biopsies each). The fine-tuned model achieved 0.76 area under the receiver operating characteristic curve, 0.79 accuracy, 0.83 sensitivity, and 0.72 specificity, outperforming support vector machines. TTA improved predictions when labels were unavailable.
CONCLUSIONS
Pre-trained 1D-CNNs combined with efficient fine-tuning or TTA enable accurate PCa detection in small-cohort settings using real-time RS.