Feasibility of the analytical dose calculation method for Au-198 brachytherapy.

Ito Kengo, Ishikawa Yojiro, Teramura Satoshi, Yamada Takayuki

СтатьяПеревод в очереди

Аннотация

PURPOSE: A dose calculation algorithm Computed Tomography (CT)-based analytical dose calculation method (CTanly), which can correct for subject inhomogeneity and size-dependent scatter doses, was applied to the 198Au seed. In this study, we evaluated the effectiveness of the CTanly method by comparing the gold standard Monte Carlo (MC) method and the conventional TG43 method on two virtual phantoms and patient CT images simulating oral cancer.

METHODS

As virtual phantoms, a water phantom and a heterogeneous phantom with soft tissue inserted cubic fat, lung, and bone were used. A 2-mm-thick lead plate was also inserted into the heterogeneous phantom as a dose attenuator. Virtual 198Au seeds and a 2-mm-thick lead plate were placed on the patient CT images. Dose distributions obtained via the TG43 and CTanly methods were compared with those of the MC by gamma analysis with 2%/2-mm thresholds. The computation durations were also compared.

RESULTS

In the water phantom, dose distributions comparable to those obtained via the MC method were obtained regardless of the algorithm. For the inhomogeneity phantom and patient case, the CTanly method showed an improvement in the gamma passing rate and dose distributions similar to those of the MC method were obtained. The computation time, which was days with the MC method, was reduced to minutes with the CTanly method.

CONCLUSIONS

The CTanly method is effective for 198Au seed dose calculations and takes a shorter time to obtain the dose distributions than the MC method.

Для цитирования: Ito Kengo, Ishikawa Yojiro, Teramura Satoshi, Yamada Takayuki. Feasibility of the analytical dose calculation method for Au-198 brachytherapy.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2024. DOI: 10.1016/j.ejmp.2024.104501.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.