MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2012.01.020

Медицинская библиотека · Journal of shoulder and elbow surgery · 2012

Acromioclavicular joint reconstruction: a comparative biomechanical study of three techniques.

Lädermann Alexandre, Gueorguiev Boyko, Stimec Bojan, Fasel Jean, Rothstock Stephan, Hoffmeyer Pierre

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Acute acromioclavicular joint dislocations indicated for surgery can be treated with several stabilization techniques. This in vitro study evaluated the acromioclavicular joint stability after 3 types of validated repair techniques compared with the native situation.

MATERIALS AND

METHODS

Nine pairs (right-left) of intact cadaveric shoulder specimens were assigned to 3 study groups with randomly distributed samples according to the coracoclavicular distance. The groups were instrumented with acromioclavicular and coracoclavicular cerclages (CE), a Twin Tail TightRope (TR), or a locking compression superior and anterior clavicle plate (CP). Native and instrumented specimens were tested quasi-static nondestructively (superior: 70 N; anteroposterior: ± 35 N, 10 mm/min) and cyclically until failure (superior, valley load: 20 N; initial peak load: 70 N; increment: 0.02 N/cycle).

RESULTS

The TR study group showed the highest (in N/mm) superoinferior (73.77 ± 14.04) and anteroposterior (29.58 ± 1.52) stiffness, followed by CE (superoinferior: 59.73 ± 10.33; anteroposterior: 24.31 ± 4.14) and CP (superoinferior: 24.08 ± 5.29). Instrumentation generally led to increased superoinferior and anteroposterior stiffness in each study group but to a significant superoinferior stiffness reduction for CP (P = .029). Significantly lower coracoclavicular displacement at valley load after 1 and 500 cycles was observed for TR (P = .018) and CE (P = .041) compared with CP. Cycles to failure were significantly higher in CE (7298 ± 1244 cycles, P = .011) and TR (4434 ± 727 cycles, P = .031) compared with CP (1683 ± 509 cycles).

CONCLUSIONS

The CE and TR techniques led to similar biomechanical performances. The CE repair might mimic the native acromioclavicular joint stiffness better than the other 2 setups, leading to more physiological stabilization.

Для цитирования: Lädermann Alexandre, Gueorguiev Boyko, Stimec Bojan, Fasel Jean, Rothstock Stephan, Hoffmeyer Pierre. Acromioclavicular joint reconstruction: a comparative biomechanical study of three techniques.. Journal of shoulder and elbow surgery. 2012. DOI: 10.1016/j.jse.2012.01.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.