MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11999-010-1404-7

Медицинская библиотека · Clinical orthopaedics and related research · 2010

The use of a cemented dual mobility socket to treat recurrent dislocation.

Hamadouche Moussa, Biau David J, Huten Denis, Musset Thierry, Gaucher François

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The treatment of recurrent dislocation after total hip arthroplasty remains challenging. Dual mobility sockets have been associated with a low rate of dislocation but it is not known whether they are useful for treating recurrent dislocation.

QUESTIONS/PURPOSES: We therefore asked whether a cemented dual mobility socket would (1) restore hip stability following recurrent dislocation; (2) provide a pain-free and mobile hip; and (3) show durable radiographic fixation.

METHODS

We retrospectively reviewed 51 patients treated with a cemented dual mobility socket for recurrent dislocation after total hip arthroplasty between August 2002 and June 2005. The mean age at the time of the index procedure of was 71.3 years. Of the 51 patients, 47 have had complete clinical and radiographic evaluation data at a mean followup of 51.4 months (range, 25-76.3 months).

RESULTS

The cemented dual mobility socket restored complete stability of the hip in 45 of the 47 patients (96%). The mean Merle d'Aubigné hip score was 16 ± 2 at the latest followup. Radiographic analysis revealed no or radiolucent lines less than 1 mm thick located in a single acetabular zone in 43 of 47 hips (91.5%). The cumulative survival rate of the acetabular component at 72 months using revision for dislocation and/or mechanical failure as the end point was 96% ± 4% (95% confidence interval, 90%-100%).

CONCLUSIONS

A cemented dual mobility socket was able to restore hip stability in 96% of recurrent dislocating hips. However, longer-term followup is needed to ensure that dislocation and loosening rates will not increase.

Для цитирования: Hamadouche Moussa, Biau David J, Huten Denis, Musset Thierry, Gaucher François. The use of a cemented dual mobility socket to treat recurrent dislocation.. Clinical orthopaedics and related research. 2010. DOI: 10.1007/s11999-010-1404-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.