BACKGROUND

The purpose of this study was to evaluate the role of medial support and clinical factors responsible on outcomes and major complications associated with treatment of unstable proximal humerus fractures using a locking plate and suture augmentation.

METHODS

Sixty-three cases in 62 patients (42 female, 20 male) were evaluated between September 2004 and October 2008. Cases were divided into either a medial support group (36 cases) or non-medial support group (27 cases). Clinical and radiographic evaluations included Neer's evaluation criteria, the neck-shaft angle using the Paavolainen method, and complications. We analyzed the correlation between bone- and fracture- related complications and three independent clinical variables, such as the presence of medial support, fracture type, and osteoporosis by way of multivariate logistic regression.

RESULTS

There were statistically significant differences in the overall incidence of complications based on the presence of medial support (p = 0.014) and preoperative fracture type (p = 0.018), but no differences based on the presence of osteoporosis (p = 0.157). According to multivariate logistic regression analysis, the restoration of medial support was the most reliable factor to prevent bone- and fracture- related complications. In addition, when we compared the incidence of bone- and fracture-related complications in the presence or absence of medial support among 30 patients with osteoporosis, the group with restoration of medial support had only one complication of humeral head osteonecrosis despite the presence of osteoporosis (5.9% vs. 46.2%, p = 0.025). According to Neer's criteria, excellent or satisfactory clinical results accounted for seventy-three percent of the total cases (46 of 63 cases). Seventy-eight percent (49 of 55 cases) showed good radiographic results by the Paavolainen method. There were 14 complications in 13 of 63 cases (20.6%).

CONCLUSIONS

In the treatment of unstable proximal humerus fractures with locking plate technology and suture augmentation, we suggest that obtaining medial support is an important factor in preventing major bone- and fracture-related postoperative complications such as reduction loss or nonunion.

Для цитирования: Jung Woo-Bin, Moon Eun-Sun, Kim Sung-Kyu, Kovacevic David, Kim Myung-Sun. Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate?. BMC musculoskeletal disorders. 2013. DOI: 10.1186/1471-2474-14-102.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.