MedElevator Войти в исследования
← Поиск публикаций

DOI 10.52312/jdrs.2024.1611

Медицинская библиотека · Joint diseases and related surgery · 2024

Comparison between CFR-PEEK and titanium plate for proximal humeral fracture: A meta-analysis.

Song Li-Ming, Wang Gui-Xin, Wang Lei

СтатьяМетаанализСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

The aim of the present meta-analysis was to compare the efficacy and safety of the carbon fiber-reinforced polyetheretherketone (CFR-PEEK) and titanium plate for the treatment of proximal humeral fractures (PHFs) from clinical comparative trials.

MATERIALS AND

METHODS

A comprehensive search of English databases was carried out, such as PubMed, Web of Science, ScienceDirect, Springer and Cochrane Library databases. The RevMan version 5.1 software was applied for statistical analysis, and the mean difference (MD) and risk difference (RD) as the combined variables, and "95%" as the confidence interval (CIs).

RESULTS

One randomized-controlled trial and five retrospective controlled studies including 282 PHFs were considered eligible and finally included. Meta-analysis demonstrated that there were significant differences in Constant score (CS) (MD=9.23; 95% CI: 5.02, 13.44; p<0.0001), anterior elevation (MD=18.83; 95% CI: 6.27, 31.38; p=0.003), lateral elevation (MD=18.42; 95% CI: 3.64, 33.19; p=0.01) and adduction (MD=3.53; 95% CI: 0.22, 6.84; p=0.04). No significant differences were observed regarding Constant score compared to the contralateral shoulder, Oxford Shoulder Score, internal rotation, external rotation, screw perforation and cutout, varus/valgus malalignment, humeral head collapse/necrosis, implant removal, and revision surgery between the two groups.

CONCLUSION

Compared to titanium plate, CFR-PEEK plate showed better Constant score, anterior elevation, lateral elevation and adduction in treating PHFs. The complications are comparable to those achieved with conventional titanium plates.

Для цитирования: Song Li-Ming, Wang Gui-Xin, Wang Lei. Comparison between CFR-PEEK and titanium plate for proximal humeral fracture: A meta-analysis.. Joint diseases and related surgery. 2024. DOI: 10.52312/jdrs.2024.1611.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.