MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijscr.2024.110044

Медицинская библиотека · International journal of surgery case reports · 2024

A case of recurrent proximal femoral fracture after open reduction and internal fixation with bilateral locking plates for a Rorabeck type II periprosthetic fracture.

Li Xiaobing, Xu Wenhe, Yin Yongqiang, Zhang Xu, Xiong Zhizheng, Yang Yuanqing

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION AND

IMPORTANCE

Periprosthetic distal femur fractures (PDFFs) are rare complications that may occur during or after total knee arthroplasty (TKA). The incidence of PDFFs is increasing. Plate internal fixation has demonstrated positive results. However, there is limited research available on the recurrence of periimplant fractures following open reduction and internal fixation with bilateral locking plates.

CASE PRESENTATION: A 70-year-old female patient was diagnosed with a Rorabeck type II fracture. Based on the patient's physical condition and available surgical options, minimally invasive open reduction, bilateral plate fixation, and allograft artificial bone grafting were chosen. The postoperative recovery was successful. However, the patient experienced a fall 2 months after the surgery, resulting in a proximal femoral fracture. After considering the patient's condition and family preferences, conservative treatment was ultimately decided upon.

CLINICAL DISCUSSION: Minimally invasive bilateral Locking Compression Plate (LCP) as a surgical approach can effectively reduce surgical risks prior to the procedure. Careful selection of screws and the use of C-arm fluoroscopy during plate contouring and fixation are essential to prevent screw penetration through the contralateral cortex. Treatment outcomes were not impacted in patients with normal bone mass; however, in this particular case, the patient had severe osteoporosis, significantly increasing the risk of refracture. It is crucial to improve postoperative monitoring and raise awareness about safety among patients and their families.

CONCLUSION

The management of periprosthetic distal femur fractures (PDFFs) is influenced by the type of fracture and bone quality. Mechanical stability and stress dispersion of internal fixation are key factors to consider. In the perioperative setting, involving experienced clinicians is essential to reduce the risk of secondary injuries that may impact treatment outcomes, especially when choosing screws for fixation in patients with low bone density.

Для цитирования: Li Xiaobing, Xu Wenhe, Yin Yongqiang, Zhang Xu, Xiong Zhizheng, Yang Yuanqing. A case of recurrent proximal femoral fracture after open reduction and internal fixation with bilateral locking plates for a Rorabeck type II periprosthetic fracture.. International journal of surgery case reports. 2024. DOI: 10.1016/j.ijscr.2024.110044.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.