MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-025-05910-z

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2025

The influence of casting techniques on the redisplacement risk of reduced distal radius fractures in adults.

Barvelink B, Kok M J, Smidt S, Lakwijk K F C, Verhaar J A N, Reijman M, Colaris J W

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Successfully reduced distal radius fractures (DRFs) often redisplace while casted. Poor cast moulding might be a risk factor for redisplacement of DRFs. This study aims to assess whether cast moulding quality, as determined by casting indices, impact the risk of redisplacement. Also, we assessed the influence of the cast applicant and the material used on the redisplacement risk.

MATERIALS AND

METHODS

We retrospectively reviewed cases from a prospective cohort (trial registration NL8311). We included 172 adequately reduced and circumferentially casted DRFs with a complete two-week radiographic follow-up. Fracture alignment was measured on all radiographs (trauma, post-reduction and follow-up) in accordance with the Dutch guideline for DRFs. When unacceptably aligned after 2 weeks, the DRF was labelled as redisplaced. Cast moulding quality was measured using the Three Point Index (TPI), Cast Index (CI) and Gap Index (GI). A TPI > 0.8, CI > 0.7 and GI > 0.15 implicates poor cast moulding. Multivariable logistic regression was used to examine the influence of cast moulding quality, cast applicant and casting material on the redisplacement risk. We corrected for patient age, intra-articular involvement, the degree of radial inclination and radial shortening.

RESULTS

Redisplacement occurred in 40% of DRFs. The mean index scores were poor (TPI 0.94, CI 0.85, GI 0.22), indicating generally suboptimal cast moulding quality. None of the cast indices were significantly associated to redisplacement (OR [95% CI]: TPI 1.2 [0.6 to 2.5], CI 2.4 [0.7 to 15.7], GI 1.6 [0.7 to 4.0]). DRFs casted by nurse practitioners had significantly lower odds of redisplacement compared to those casted by emergency room nurses. Type of casting (synthetic versus plaster of Paris) was not associated with redisplacement.

CONCLUSIONS

Cast moulding quality, measured using cast indices, is not associated with redisplacement of reduced DRFs. Casts applied by nurse practitioners redisplaced significantly less often.

LEVEL OF EVIDENCE: Therapeutic Studies level III.

Для цитирования: Barvelink B, Kok M J, Smidt S, Lakwijk K F C, Verhaar J A N, Reijman M, Colaris J W. The influence of casting techniques on the redisplacement risk of reduced distal radius fractures in adults.. Archives of orthopaedic and trauma surgery. 2025. DOI: 10.1007/s00402-025-05910-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.