The effect of graft fixation angles on anteroposterior and rotational knee laxity in double-bundle anterior cruciate ligament reconstruction: evaluation using computerized navigation.

Koga Hideyuki, Muneta Takeshi, Yagishita Kazuyoshi, Ju Young-Jin, Sekiya Ichiro

СтатьяПеревод в очереди

Аннотация

BACKGROUND

One of the main differences affecting outcome between single-bundle and double-bundle anterior cruciate ligament (ACL) reconstructions may be graft fixation angles and initial force settings; however, there has been little research to investigate these effects in either technique.

HYPOTHESIS: Anteroposterior and rotational knee laxities will be less in double-bundle ACL reconstructions than single-bundle reconstructions, and different graft fixation angles affect knee kinematics and pivot-shift phenomenon in double-bundle ACL reconstructions.

STUDY

DESIGN

Controlled laboratory study.

METHODS

Eleven patients who underwent double-bundle ACL reconstruction were included in this study. The anteromedial bundle (AMB) and the posterolateral bundle (PLB) were provisionally fixed to a graft tensioning system during surgery. The graft fixation settings were as follows: (1) AMB only at 20° (A20), (2) PLB only at 20° (P20), (3) AMB at 20° and PLB at 0° (A20P0), (4) AMB at 20° and PLB at 20° (A20P20), and (5) AMB at 20° and PLB at 45° (A20P45). All the grafts were tensioned at a constant stress level. Anterior tibial translation (ATT), internal rotation (IR), and external rotation (ER) at 30° and 90° of knee flexion applied with manual maximum load were measured before graft insertion and in each setting using a navigation system. A pivot-shift test was also evaluated manually with modified International Knee Documentation Committee criteria in each setting.

RESULTS

A20 was less constrained than A20P20 and A20P45 in ATT at 30° and less constrained than A20P45 in IR at 30°. P20 was less constrained than any other settings in ATT at 30° and less constrained than A20P45 in IR at 30°. A20P0 was less constrained than A20P45 in IR at 30° and in ER at 30°. Grade 1 pivot-shift phenomenon persisted in 8 cases in P20, in 4 cases in A20, and in 3 cases in A20P0, whereas no case showed a positive pivot-shift result in A20P20 and A20P45.

CONCLUSION

In this in vivo laboratory model, double-bundle ACL reconstruction with fixation of AMB at 20° and PLB at 20° or 45° restored better stability than single AMB or single PLB reconstruction in which the graft was of smaller size.

CLINICAL RELEVANCE: In double-bundle ACL reconstruction, fixation of the PLB at 0° might be looser and function worse compared with that of PLB at 20° or 45° when the AMB is fixed at 20°, with the individual variability that should lead to caution until it can be better assessed by surgeons.

Для цитирования: Koga Hideyuki, Muneta Takeshi, Yagishita Kazuyoshi, Ju Young-Jin, Sekiya Ichiro. The effect of graft fixation angles on anteroposterior and rotational knee laxity in double-bundle anterior cruciate ligament reconstruction: evaluation using computerized navigation.. The American journal of sports medicine. 2011. DOI: 10.1177/0363546511426696.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.