BACKGROUND

Successful fixation of the greater trochanter (GT) in total hip arthroplasty (THA) is a challenging task. A wide range of clinical results are reported in the literature despite advancements in fixation technology. Previous studies may have lacked adequate sample sizes to detect differences. This study evaluates nonunion and reoperation rates and determines factors influencing successful fixation of the GT using current-generation cable plate devices.

METHODS

This retrospective cohort study included 76 patients who underwent surgery requiring fixation of their GT and had at least 1-year radiographic follow-up. Indications for a surgery were periprosthetic fracture (n = 25), revision THA requiring an extended trochanteric osteotomy (n = 30), GT fracture (n = 3), GT fracture nonunion (n = 9), and complex primary THA (n = 3). Primary outcomes were radiographic union and reoperation. Secondary objectives were patient and plate factors influencing radiographic union.

RESULTS

At a mean radiographic follow-up of 2.5 years, the union rate was 76.3% with a nonunion rate of 23.7%. Twenty-eight patients underwent plate removal, reasons for removal were pain (n = 21), nonunion (n = 5), and hardware failure (n = 2). Seven patients had cable-induced bone loss. Anatomic positioning of the plate (P = .03) and number of cables used (P = .03) were associated with radiographic union. Nonunion was associated with a higher incidence (+30%) of hardware failure due to broken cable(s) (P = .005).

CONCLUSIONS

Greater trochanteric nonunion remains a problem in THA. Successful fixation using current-generation cable plate devices may be influenced by plate positioning and number of cables used. Plate removal may be required for pain or cable-induced bone loss.

Для цитирования: Schafer Patrick, Sullivan Thomas C, Lambert Bradley, Park Kwan J, Clyburn Terry A, Incavo Stephen J. Greater Trochanteric Fixation Using Cable Plate Devices in Complex Primary and Revision Total Hip Arthroplasty.. Arthroplasty today. 2023. DOI: 10.1016/j.artd.2023.101103.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.