m+Medelevator.RU
← Поиск публикаций
Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2005

Absorbable implants for open shoulder stabilization. A 7-8-year clinical and radiographic follow-up.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Magnusson Lennart, Ejerhed Lars, Rostgård Lars, Sernert Ninni, Kartus Jüri

Аннотация

Eighteen consecutive patients who had recurrent, unidirectional, post-traumatic shoulder instability were included. All these patients underwent surgery using an open Bankart technique involving absorbable suture anchors. The median age at the index operation was 27 (16-50) years. One subluxation and two re-dislocations occurred during the follow-up period of 90 (80-95) months. At the 90-month control, the Rowe and Constant scores were 94 (63-100) points and 88.5 (65-100) points, respectively. The strength measurements on the index side in 90 degrees abduction revealed 8.1 (3.7-17.2) kg compared with 7.6 (2.7-17.6) kg on the contra lateral side (n.s.). The external rotation in abduction was 80 (60-95) degrees compared with 100 (70-120) degrees for the contra lateral side (p = 0.0015). Signs of minor or moderate degeneration were found in five of 18 patients (28%) on the preoperative radiographs. There was a significant continuous increase in degenerative changes during the follow-up period as seen on the seven, 33 and 90-month radiographs (p = 0.01, 0.03 and 0.01, respectively). On the 90-month radiographs, 12 of 18 patients (67%) had minor, moderate or severe degenerative changes (p = 0.0004 preoperative vs. 90 months). On the 7-month radiographs, two of 18 patients (11%) had invisible or hardly visible drill holes in conjunction with the absorbable implants. On the 90-month radiographs, 12 of 18 patients (67%) had invisible or hardly visible drill holes (p = 0.003 7 months vs. 90 months). In the long term, the method resulted in stable, well-functioning shoulders in 15 of 18 patients (83%). The stabilisation was not, however, able to prevent further increases in radiographic degenerative changes during the 7-8-year follow-up. The drill holes used for the absorbable suture anchors appeared to heal in the majority of patients during the follow-up period.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты