MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/sjopt.sjopt_164_23

Медицинская библиотека · Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society · 2024

Comparison of focal loss volume, global loss volume, retinal nerve fiber layer thickness, and corneal epithelial thickness in eyes with glaucoma and suspicious optic discs.

Ibrahim Hani M G

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to study the role of the focal loss volume (FLV), global loss volume (GLV), and other spectral-domain optical coherence tomography (SD-OCT) parameters in early diagnosis of glaucomatous damage.

METHODS

A retrospective study included records of 34 eyes with early glaucoma (Group A) and 17 eyes with suspicious optic discs (Group B). Retinal nerve fiber layer (RNFL), ganglion cell complex (GCC), and corneal thickness parameters were assessed by the SD OCT (RTVue SD-OCT). These included the FLV, GLV, in addition to RNFL thickness, cup/disc ratio, GCC thickness, and anterior segment OCT for assessment of central corneal thickness and central corneal epithelial thickness. Data from both groups were subjected to statistical analysis.

RESULTS

The FLV and GLV had the highest areas under the receiver operating characteristic curve in Group A eyes. FLV had higher (97.2%) specificity and was the earliest parameter to be affected by glaucomatous damage, followed by GLV. Moreover, Group A eyes had significant thinning of the RNFL (91.59 μm) compared to Group B (118.18 μm), and GCC thickness was also significantly thinner in Group A (92.07 μm) than in Group B (110.54 μm). Interestingly, Group A eyes had thinner corneal epithelium (nonsignificant) than Group B.

CONCLUSION

FLV and GLV were of the greatest value in the assessment of early glaucomatous GCC degeneration.

Для цитирования: Ibrahim Hani M G. Comparison of focal loss volume, global loss volume, retinal nerve fiber layer thickness, and corneal epithelial thickness in eyes with glaucoma and suspicious optic discs.. Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society. 2024. DOI: 10.4103/sjopt.sjopt_164_23.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.