MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bsd.0b013e3181e9f249

Медицинская библиотека · Journal of spinal disorders & techniques · 2011

Kidney-type intervertebral spacers should be located anteriorly in cantilever transforaminal lumbar interbody fusion: analyses of risk factors for spacer subsidence for a minimum of 2 years.

Fukuta Shoji, Miyamoto Kei, Hosoe Hideo, Shimizu Katsuji

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective analysis of factors related to kidney-type interbody spacer subsidence (SS) in transforaminal interbody fusion (TLIF).

OBJECTIVE

To determine the risk factors for SS in TLIF using kidney-type spacers.

SUMMARY OF BACKGROUND DATA: SS into the vertebral body, a major complication of TLIF, has not been studied extensively.

METHODS

Between July 2004 and May 2006, 54 consecutive patients with lumbar dysplastic changes or degenerative disc diseases underwent TLIF using 82 kidney-type spacers with iliac bone grafts. All were followed-up for more than 2 years (mean, 2 y, 11 mo). SS was defined as disc height loss >2 mm. Risk factors analyzed for SS included spacer location in the intervertebral space (IVS, anterior, center, and posterior), sex, age, body mass index, and disease (spondylolisthesis, degenerative disc disease). Clinical outcomes were assessed using the Japanese Orthopedic Associated Score for back pain, as were adjacent segment disorder and nonunion.

RESULTS

Of the 82 spacers, 66 were located in the center of the IVS and 16 anteriorly. There were 18 SS. Spacer position at the center of the IVS (P<0.001) and older age (P<0.001) were significantly associated with SS, with the first 2 factors having a synergistic effect. Adjacent level disorder (n=5) and nonunion (n=3) were observed only in patients with spacers positioned at the center of the IVS.

CONCLUSIONS

Kidney-type spacers should be located in the anterior portion of the IVS to prevent subsidence of the intervertebral body, especially in patients with elderly age.

Для цитирования: Fukuta Shoji, Miyamoto Kei, Hosoe Hideo, Shimizu Katsuji. Kidney-type intervertebral spacers should be located anteriorly in cantilever transforaminal lumbar interbody fusion: analyses of risk factors for spacer subsidence for a minimum of 2 years.. Journal of spinal disorders & techniques. 2011. DOI: 10.1097/bsd.0b013e3181e9f249.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.