MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2025.112159

Медицинская библиотека · European journal of radiology · 2025

The Association between opportunistic DECT-derived bone values and vertebral fracture status.

Reschke Philipp, Koch Vitali, Sommer Christof M, Gotta Jennifer, Höhne Elena, Booz Christian, D'Angelo Tommaso, Eichler Katrin, Vogl Thomas J, Gruenewald Leon D

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Osteoporosis is a major cause of spinal insufficiency fractures but often remains underdiagnosed. Dual-energy CT (DECT) enables reliable assessment of bone mineral density (BMD), but its limited accessibility highlights the need for alternative metrics. This study investigates the association between vertebral fracture status, DECT-derived BMD and alternative bone quality assessments, including Hounsfield Unit (HU)-based assessment and cortical thickness ratio.

METHODS

A total of 180 patients who underwent non-contrast DECT of the spine between January 2016 and December 2021 were retrospectively analyzed. All imaged vertebrae were assessed for acute insufficiency fractures. DECT-based BMD was assessed using a dedicated postprocessing software that applies material decomposition and compared with HU-based assessment and cortical thickness ratio. Statistical analysis included correlation analysis, logistic regression adjusted for age and sex, ROC and PR curve analyses.

RESULTS

Among 180 patients (97 females, median age of 65 years), 126 subjects (70 %) were confirmed to have insufficiency fractures. Patients with fractures had significantly lower values for DECT-based BMD (98.3 vs. 123.7 mg/cm3, p < 0.001), trabecular HU (93.5 vs. 159.5 HU, p < 0.001), and cortical thickness ratio (1.065 vs. 1.05, p < 0.001). Cortical HU showed no significant difference between patients with and without fractures (p = 0.35). DECT-based BMD provided the highest diagnostic accuracy for detecting insufficiency fractures, yielding an AUC of 0.8 for the ROC curve and an AUC of 0.9 for the PR curve. HU-based measurements (trabecular HU: Spearman ρ = 0.17; cortical HU: ρ = 0.2) and the cortical thickness ratio (ρ = -0.01) demonstrated only weak correlations with the reference standard, DECT-derived BMD.

CONCLUSION

DECT-based BMD demonstrated the highest diagnostic accuracy for insufficiency fractures. HU-based assessments and cortical thickness ratio showed only weak correlations with DECT-based BMD, limiting their reliability as alternatives.

Для цитирования: Reschke Philipp, Koch Vitali, Sommer Christof M, Gotta Jennifer, Höhne Elena, Booz Christian, D'Angelo Tommaso, Eichler Katrin, Vogl Thomas J, Gruenewald Leon D. The Association between opportunistic DECT-derived bone values and vertebral fracture status.. European journal of radiology. 2025. DOI: 10.1016/j.ejrad.2025.112159.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.