DOI 10.4085/1062-6050-46.3.257
Differential ability of selected postural-control measures in the prediction of chronic ankle instability status.
Аннотация
CONTEXT: Chronic ankle instability (CAl) is a term used to identify a condition associated with recurrent ankle sprains and persistent symptoms. Balance deficits, evaluated using center-of-pressure (COP) force-plate measurements, have been shown to occur in people with CAl.
OBJECTIVE
To determine the differential abilities of selected force-plate postural-control measures to assess CAl.
DESIGN
Case-control study.
SETTING
Laboratory.
PATIENTS OR OTHER
PARTICIPANTS
A total of 63 individuals with CAl (30 men, 33 women: age= 22.3± 3.7 years, height= 169.8 ±9.6 cm, mass= 70.7± 14.3 kg) and 46 healthy controls (22 men, 24 women: age= 21.2± 4.1 years, height= 173.3± 9.2 cm, mass =69.2± 13.2 kg) volunteered.
INTERVENTION(S): Participants performed 3 10-second trials of quiet, single-limb stance on a force plate under 2 conditions: eyes open and eyes closed.
MAIN OUTCOME MEASURE(S): Measures of COP area, COP velocity, COP SO, COP range of excursion, percentage of COP range used, time-to-boundary absolute minimum, time-to-boundary mean of the minima, and time-to-boundary SO of the minima were calculated. All measures with the exception of COP area were calculated in both the mediolateral (ML) and anteroposterior directions. For each measure, a receiver operator curve analysis was created, and the corresponding area under the curve was tested. The optimal diagnostic threshold value for each measure was determined, and the corresponding positive and negative likelihood ratios were calculated.
RESULTS
Three eyes-closed, single-limb force-plate measures (COP ML SO, ML percentage of COP range used, and time-to-boundary absolute minimum) predicted CAl status. However, all 3 measures had positive likelihood ratios associated with only small shifts in the probability of a patient with a positive test having CAl and negative likelihood ratios associated with very small shifts in the probability of a patient with a negative test not having CAl.
CONCLUSIONS
No single force-plate measure was very effective in predicting if an individual had CAl or not.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.