MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.14112

Медицинская библиотека · Veterinary surgery : VS · 2024

Virtual surgical planning and use of a 3D-printed, patient-specific reduction system for minimally invasive plate osteosynthesis of diaphyseal tibial fractures in dogs: A historic case control study.

Scheuermann Logan M, Lewis Daniel D, Johnson Matthew D, Biedrzycki Adam H, Kim Stanley E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the efficacy and clinical outcomes of computed tomography (CT)-based virtual surgical planning (VSP) and a three-dimensional (3D)-printed, patient-specific reduction system to conventional indirect reduction techniques for diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO) in dogs.

STUDY

DESIGN

A prospective clinical study with a historic control cohort.

SAMPLE POPULATION: Dogs undergoing MIPO stabilization of diaphyseal tibial fractures using a custom 3D-printed reduction system (3D-MIPO; n = 15) or conventional indirect reduction techniques (c-MIPO; n = 14).

METHODS

Dogs were prospectively enrolled to the 3D-MIPO group and CT scans were used to design and fabricate a custom 3D-printed reduction system to facilitate MIPO. Medical records were searched to identify dogs for the c-MIPO group. Pre-, intra- and postoperative parameters were compared between groups.

RESULTS

The duration from presentation until surgery was 23 h longer in the 3D-MIPO group (p = .002). Fewer intraoperative fluoroscopic images were acquired (p < .001) and mean surgical duration was 34 min shorter in the 3D-MIPO group (p = .014). Median postoperative tibial length, frontal alignment, and sagittal alignment were within 4 mm, 3° and 3°, respectively, of the contralateral tibia in both groups and did not differ between reduction groups (p > .1). Postoperative complications occurred in 27% and 14% of fractures in the 3D-MIPO and c-MIPO groups, respectively.

CONCLUSION

Both reduction methods yielded comparable results. Although the preoperative planning and guide preparation was time consuming, surgery times were shorter and fluoroscopy use was less in the 3D-MIPO group.

CLINICAL SIGNIFICANCE: VSP and the custom 3D-printed reduction system facilitated efficient MIPO.

Для цитирования: Scheuermann Logan M, Lewis Daniel D, Johnson Matthew D, Biedrzycki Adam H, Kim Stanley E. Virtual surgical planning and use of a 3D-printed, patient-specific reduction system for minimally invasive plate osteosynthesis of diaphyseal tibial fractures in dogs: A historic case control study.. Veterinary surgery : VS. 2024. DOI: 10.1111/vsu.14112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.