PURPOSE: To assess the volume-dependent sensitivity of the Focused Assessment with Sonography for Trauma (FAST) and to analyse regional detection performance under controlled in-vivo conditions.

METHODS

In this prospective single-centre study, sequential intraperitoneal instillation of 0.9% NaCl (250-1500 mL) was performed during elective laparoscopic procedures in 35 adults. Standardised FAST examinations were conducted by two experienced sonographers using transverse and longitudinal views of Morison's pouch, the Douglas recess, and Koller's space. Sensitivity was calculated for each instilled volume and anatomical region. Specificity could not be assessed due to the experimental design with mandatory fluid presence. Regional differences were tested using one-way ANOVA, and a Monte Carlo simulation (1000 resamples) evaluated detection stability across body-mass-index (BMI) groups.

RESULTS

FAST sensitivity increased with volume: 14.3% (95% CI 4.8-30.3) at 250 mL, 37.1% (21.5-55.1) at 500 mL, 74.3% (56.7-87.5) at 1000 mL, and 91.4% (76.9-98.2) at 1500 mL. The highest detection rate occurred in Morison's pouch, followed by the Douglas and Koller recesses. Longitudinal scanning of the Douglas pouch improved sensitivity by > 20% compared with the transverse view. ANOVA confirmed significant regional variability (F(5, 153) = 4.37, p = 0.001, η² = 0.125). Detection rates declined in participants with BMI ≥ 30 kg/m² non-significantly, while instilled volume remained the dominant predictor (OR > 20 for 1500 mL vs. 250 mL).

CONCLUSIONS

FAST sensitivity is strongly volume-dependent, with reliable detection achieved only beyond 1000 mL. Incorporating longitudinal pelvic views-particularly of the Douglas pouch-significantly enhances diagnostic accuracy. These findings support refinement of FAST training and underscore the need for clinical correlation and adjunct imaging when FAST results are negative in unstable trauma patients.

Для цитирования: Güsgen Christoph, Nada Andreas, Kornek Miroslaw T, Willms Arnulf, Schaaf Sebastian. Volume-dependent detection of free intraperitoneal fluid by FAST: a prospective in-vivo study with sequential fluid instillation.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2026. DOI: 10.1007/s00068-026-03262-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.