MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-023-03529-7

Медицинская библиотека · Journal of orthopaedic surgery and research · 2023

Arthroscopic treatment of unstable scaphoid fracture and nonunion with two headless compression screws and distal radius bone graft.

Cheng Cong, Jiang Zongyuan, Sun Haoran, Hu Jiaping, Ouyang Yanggang

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The treatment of unstable scaphoid fracture and nonunion remains a challenging problem for hand surgeons. Minimally invasive treatment has become the preferred method of treatment.

PURPOSE: This study introduces the arthroscopic technique with two headless compression screws (HCS) fixation and distal radius bone grafting for the treatment of unstable scaphoid fracture and nonunion, aiming to evaluate its clinical and radiological outcomes.

METHODS

It was a retrospective study. From January 2019 to February 2021, a total of 23 patients were included in the current study. Among them, 13 patients with unstable scaphoid fracture underwent arthroscopic treatment with two HCS; 10 patients with scaphoid nonunion underwent arthroscopic treatment with two HCS and a distal radius bone graft. The range of motion of the wrist, visual analog scale (VAS), grip strength, the Modified Mayo Wrist Score (MMWS), the Patient-Rated Wrist Evaluation (PRWE) score, and the Disability of the Arm, Shoulder and Hand (DASH) score were collected at preoperatively and the final follow-up. A computed tomography scan of the wrist was performed on each patient to analyze for union and postoperative osteoarthritis during the follow-up period.

RESULTS

Significant improvement was only observed in wrist extension. Clinical outcomes including grip strength, VAS pain score, MMWS, PRWE score, and DASH score were significantly improved at the final follow-up. In the subgroup analysis, both patients stabilized with either two HCS or a distal radius bone graft and two HCS have improved clinical outcomes after surgery, respectively. All patients achieved union. No screw fixation failure occurred, and no other postoperative complication was observed in any of the patients.

CONCLUSIONS

The arthroscopic technique with two-HCS fixation and distal radius bone grafting is a reliable and effective technique for the treatment of unstable scaphoid fracture and nonunion, providing satisfactory union rates and clinical outcomes.

Для цитирования: Cheng Cong, Jiang Zongyuan, Sun Haoran, Hu Jiaping, Ouyang Yanggang. Arthroscopic treatment of unstable scaphoid fracture and nonunion with two headless compression screws and distal radius bone graft.. Journal of orthopaedic surgery and research. 2023. DOI: 10.1186/s13018-023-03529-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.