Percutaneous treatment of type C distal radius fractures using dual-external fixator.
Аннотация
BACKGROUND
This study aimed to introduce a potential alternative percutaneous treatment for AO types C1, C2, and C3 distal radius fractures using dual-external fixator (a no-bridging cemented-pin frame and a conventional wrist-bridging external fixator).
MATERIALS AND
METHODS
From January 2018 to January 2021, 52 patients (52 distal radius fractures) were treated with dual-external fixator. For comparison, 61 patients (61 distal radius fractures) were treated with a plate and screw system. Wrist function was assessed using the Mayo Wrist Score. Patient satisfaction was assessed using the Short Assessment of Patient Satisfaction. A P < 0.05 was considered statistically significant.
RESULTS
Fracture healing was achieved in all patients. At the final follow-up of 29 months (range, 24-34 months) vs 36 months (range, 26-39 months) (P > 0.05), the patients treated with dual-external fixator and a plate and screw system achieved mean ulnar deviations of 31° vs 29° (P < 0.05), mean Mayo Wrist Scores of 91.12 ± 5.98 vs 88.12 ± 7.54 (P < 0.05), and mean patient satisfaction scores of 23.42 ± 2.47 vs 23.04 ± 2.32 (P > 0.05).
CONCLUSIONS
AO types C1, C2, and C3 distal radius fractures can be treated successfully using dual-external fixator. The technique is a potential alternative in addition to the conventional treatments.
LEVEL OF EVIDENCE: Level IIa.