MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12879-026-12740-w

Медицинская библиотека · BMC infectious diseases · 2026

Preliminary assessment of the use of targeted next-generation sequencing technology for detecting lymph node tuberculosis using ultrasound-guided core needle biopsy specimens.

Zhou Lihong, Zhu Huihuan, Xu Cong, Zou Xingwu, Wen Boping, Hu Qin

СтатьяОценочное исследованиеПеревод в очереди

Аннотация

PURPOSE: The current study aimed to evaluate the diagnostic utility of targeted next-generation sequencing (tNGS) technology in detecting lymph node tuberculosis (LNTB) using ultrasound-guided puncture core needle biopsy (CNB) samples.

METHODS

This study was conducted on patients who underwent ultrasound-guided CNB operation. The samples obtained were used for the tNGS assay, mycobacterial tuberculosis (MTB) culture, Xpert MTB/RIF assay, and pathological examination. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve (AUC) of these assays were calculated. Then, their diagnostic efficacy was compared with that of the composite reference standard.

RESULTS

The sensitivity, specificity, PPV, NPV, and AUC of the tNGS assay for detecting LNTB were 95.4%, 88.9%, 98.4%, 72.7%, and 0.921, respectively. Those of the MTB culture were 26.2%, 100.0%, 100.0%, 15.8%, and 0.631, respectively. Those of the Xpert MTB/RIF assay were 72.3%, 100.0%, 100.0%, 33.3%, and 0.862, respectively. Those of the pathological examination were 80.0%, 88.9%, 98.1%, 38.1%, and 0.844, respectively. Among the tests, the tNGS assay had the highest sensitivity, and the results significantly differed among the methods.

CONCLUSION

The tNGS assay using CNB samples had a superior diagnostic efficacy for diagnosing LNTB. Hence, it has potential in clinical application. CLINICAL TRIAL: Not applicable.

Для цитирования: Zhou Lihong, Zhu Huihuan, Xu Cong, Zou Xingwu, Wen Boping, Hu Qin. Preliminary assessment of the use of targeted next-generation sequencing technology for detecting lymph node tuberculosis using ultrasound-guided core needle biopsy specimens.. BMC infectious diseases. 2026. DOI: 10.1186/s12879-026-12740-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.