DOI 10.1186/s12891-025-08602-2
Vision transformer-based diagnosis of lumbar disc herniation with grad-CAM interpretability in CT imaging.
Аннотация
BACKGROUND
In this study, a computed tomography (CT)-vision transformer (ViT) framework for diagnosing lumbar disc herniation (LDH) was proposed for the first time by taking advantage of the multidirectional advantages of CT and a ViT.
METHODS
The proposed ViT model was trained and validated on a dataset consisting of 983 patients, including 2100 CT images. We compared the performance of the ViT model with that of several convolutional neural networks (CNNs), including ResNet18, ResNet50, LeNet, AlexNet, and VGG16, across two primary tasks: vertebra localization and disc abnormality classification.
RESULTS
The integration of a ViT with CT imaging allowed the constructed model to capture the complex spatial relationships and global dependencies within scans, outperforming CNN models and achieving accuracies of 97.13% and 93.63% in terms of vertebra localization and disc abnormality classification, respectively. The performance of the model was further validated via gradient-weighted class activation mapping (Grad-CAM), providing interpretable insights into the regions of the CT scans that contributed to the model predictions.
CONCLUSION
This study demonstrated the potential of a ViT for diagnosing LDH using CT imaging. The results highlight the promising clinical applications of this approach, particularly for enhancing the diagnostic efficiency and transparency of medical AI systems.