MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2019.01.014

Медицинская библиотека · Journal of shoulder and elbow surgery · 2019

The effect of vitamin E-enhanced cross-linked polyethylene on wear in shoulder arthroplasty-a wear simulator study.

Alexander Justin J, Bell Simon N, Coghlan Jennifer, Lerf Reto, Dallmann Frank

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Wear of the polyethylene glenoid component and subsequent particle-induced osteolysis remains one of the most important modes of failure of total shoulder arthroplasty. Vitamin E is added to polyethylene to act as an antioxidant to stabilize free radicals that exist as a byproduct of irradiation used to induce cross-linking. This study was performed to assess the in vitro performance of vitamin E-enhanced polyethylene compared with conventional polyethylene in a shoulder simulator model.

METHODS

Vitamin E-enhanced, highly cross-linked glenoid components were compared with conventional ultrahigh-molecular-weight polyethylene glenoids, both articulating with a ceramic humeral head component using a shoulder joint simulator over 500,000 cycles. Unaged and artificially aged comparisons were performed. Volumetric wear was assessed by gravimetric measurement, and wear particle analysis was also subsequently performed.

RESULTS

Vitamin E-enhanced polyethylene glenoid components were found to have significantly reduced wear rates compared with conventional polyethylene in both unaged (36% reduction) and artificially aged (49% reduction) comparisons. There were no differences detected in wear particle analysis between the 2 groups.

CONCLUSION

Vitamin E-enhanced polyethylene demonstrates improved wear compared with conventional polyethylene in both unaged and artificially aged comparisons and may have clinically relevant benefits.

Для цитирования: Alexander Justin J, Bell Simon N, Coghlan Jennifer, Lerf Reto, Dallmann Frank. The effect of vitamin E-enhanced cross-linked polyethylene on wear in shoulder arthroplasty-a wear simulator study.. Journal of shoulder and elbow surgery. 2019. DOI: 10.1016/j.jse.2019.01.014.