MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.b.35507

Медицинская библиотека · Journal of biomedical materials research. Part B, Applied biomaterials · 2024

Tibial Baseplate Microstructure Governs High Cycle Fatigue Fracture In Vivo.

Kurtz Michael A, Gilbert Jeremy L, Spece Hannah, Klein Gregg R, Cates Harold E, Kurtz Steven M

СтатьяПеревод в очереди

Аннотация

Previous studies report rare occurrences of tibial baseplate fractures following primary total knee arthroplasty (TKA). However, at a microstructural scale, it remains unclear how fatigue models developed in vitro apply to fractures in vivo. In this study, we asked: (1) do any clinical factors differentiate fracture patients from a broader revision sample; and (2) in vivo, how does microstructure influence fatigue crack propagation? We identified three fractured tibial baseplates from an institutional review board exempt implant retrieval program. Then, for comparison, we collated clinical data from the same database for n = 2120 revision TKA patients with tibial trays. To identify mechanisms, we characterized fracture features using scanning electron and digital optical microscopy. Additionally, we performed cross sectional analysis using focused ion beam milling. The fracture cohort consisted of moderately to very active patients with increased implantation time (15.6 years) compared to the larger revision patient sample (5.1 years, p = 0.009). We did not find a significant difference in patient weight between the two groups (p = 0.98). Macroscopic fracture features aligned well with both previous retrieval analysis and in vitro baseplate fatigue tests. On a micron scale, we identified striations on each baseplate, demonstrating fatigue as the fracture mechanism. In vivo fatigue fracture processes depended on both the alloy (Ti-6Al-4V vs. CoCrMo) and the microstructure of the alloy formed during manufacturing. For Ti-6Al-4V, the presence of equiaxed or acicular microstructure influenced the fatigue crack propagation, the latter arising from large prior β grains and a Widmanstatten microstructure, degrading fatigue strength. CoCrMo alloy fatigue cracks propagated linearly, crystallographically influenced by planar slip. However, we did not document any features of overload or fast fracture, suggesting a high cycle, low stress fatigue regime. Ultimately, the crack profiles we present here may provide insight into fatigue fractures of modern tibial baseplates.

Для цитирования: Kurtz Michael A, Gilbert Jeremy L, Spece Hannah, Klein Gregg R, Cates Harold E, Kurtz Steven M. Tibial Baseplate Microstructure Governs High Cycle Fatigue Fracture In Vivo.. Journal of biomedical materials research. Part B, Applied biomaterials. 2024. DOI: 10.1002/jbm.b.35507.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.