MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/cid/ciag005

Медицинская библиотека · Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2026

Evaluating the Cepheid Xpert TB/LTBI Research-Use-Only Assay for Detection of Active and Latent Mycobacterium tuberculosis Infection.

Sweetser Brittney, Nguyen Hoang, Dang Hai, Katumba David, Mochizuki Tessa, Wang Qiao, Wilson Mangeni, Phan Ha, Phillips Patrick, Yerlikaya Seda, Nahid Payam, Denkinger Claudia M, Cattamanchi Adithya, Worodria William, R2D2 TB Network

Оценочное исследованиеСтатьяМногоцентровое исследованиеОценочное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Accurate nonsputum tests are essential for improving tuberculosis (TB) detection. We report the first evaluation of the Xpert TB/LTBI assay (research-use-only; Cepheid, USA), which detects 9 Mycobacterium tuberculosis antigen-stimulated mRNA targets from blood.

METHODS

We enrolled individuals ≥12 years with presumptive TB from clinics in Uganda and Vietnam. All participants underwent sputum- (liquid culture; Xpert MTB/RIF Ultra) and blood-based (Xpert TB/LTBI; QuantiFERON-TB Gold Plus [QFT-Plus]) testing. Participants were classified as having active TB (positive sputum results), latent TB infection (LTBI; positive QFT-Plus with negative sputum results), or no TB infection. Diagnostic accuracy for active TB (primary analysis) and of a 2-step algorithm that first predicted TB infection (active TB or LTBI) and then distinguished active TB from LTBI was assessed using logistic regression and receiver operating characteristic analysis.

RESULTS

Among 214 participants included, 56.5% were male, 9.3% were with HIV, 29.0% had active TB, and 31.8% had LTBI. Xpert TB/LTBI area under the curve (AUC) was 0.92 (95% CI: .88-.96) for identifying active TB, and sensitivity was 93.5% (95% CI: 84.6-97.5) and specificity 76.3% (95% CI: 69.0-82.4) at a cut-point that achieved ≥90% sensitivity. In the 2-step algorithm, Xpert TB/LTBI had high accuracy for identifying TB infection in the first step, but accuracy was lower for distinguishing active TB from LTBI in the second step.

CONCLUSIONS

Xpert TB/LTBI exceeded World Health Organization (WHO)-recommended minimum accuracy targets for a TB screening test. However, further refinement is needed to improve its ability to distinguish active TB from LTBI.

Для цитирования: Sweetser Brittney, Nguyen Hoang, Dang Hai, Katumba David, Mochizuki Tessa, Wang Qiao, Wilson Mangeni, Phan Ha, Phillips Patrick, Yerlikaya Seda, Nahid Payam, Denkinger Claudia M, Cattamanchi Adithya, Worodria William, R2D2 TB Network. Evaluating the Cepheid Xpert TB/LTBI Research-Use-Only Assay for Detection of Active and Latent Mycobacterium tuberculosis Infection.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2026. DOI: 10.1093/cid/ciag005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.