A biomechanical comparison of 3 reconstruction techniques for posterolateral instability of the knee in a cadaveric model.

Kim Sung-Jae, Kim Hyoung-Sik, Moon Hong-Kyo, Chang Woo-Hyuk, Kim Sul-Gee, Chun Yong-Min

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: The objective of this study was to compare the varus and external rotatory laxity of reconstructed knees by use of 3 different reconstruction techniques that address posterolateral instability of the knee: popliteus tendon (PT) and lateral collateral ligament (LCL) reconstruction, PT and popliteofibular ligament (PFL) reconstruction, and PFL and LCL reconstruction.

METHODS

We divided 36 fresh-frozen cadaveric knees into 3 groups of 12, and each group was assigned to a reconstruction technique: PT-LCL reconstruction with the posterior tibialis tendon, PT-PFL reconstruction with the patellar tendon and bone (Warren technique), and PFL-LCL reconstruction with the semitendinosus tendon (Larson technique). Each specimen was fixed with an Ilizarov external fixator and mounted on a custom-designed apparatus that was made to measure posterolateral instability of the knee, that is, external rotatory and varus laxity in the intact state, after cutting, and in the postoperative state at every 30 degrees from 0 degrees to 90 degrees .

RESULTS

There were no significant differences between the 3 techniques with external rotation and varus laxity in all specimens.

CONCLUSIONS

PT-LCL reconstruction was comparable to the other 2 established techniques: PT-PFL reconstruction (Warren technique) and PFL-LCL reconstruction (Larson technique). However, the original strength of the native knee could not be achieved with any of the techniques.

CLINICAL RELEVANCE: All techniques restored the posterolateral stability of the knee to near normal, with none of them being superior.

Для цитирования: Kim Sung-Jae, Kim Hyoung-Sik, Moon Hong-Kyo, Chang Woo-Hyuk, Kim Sul-Gee, Chun Yong-Min. A biomechanical comparison of 3 reconstruction techniques for posterolateral instability of the knee in a cadaveric model.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2009. DOI: 10.1016/j.arthro.2009.08.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.