DOI 10.1016/j.otsr.2012.01.008
Is it worth fixing proximal humeral fractures at increased vascular risk?
Аннотация
OBJECTIVE
To evaluate fixation of proximal humeral fractures by anterograde nailing, in terms of fracture reduction, bone healing; osteonecrosis; functional consequences of osteonecrosis and malunion.
DESIGN
Prospective, consecutive, multicenter based.
SETTING
Academic Trauma Centers; approval was received from the ethics committee of the institutions involved in the study.
METHODS
Fifty-one patients were enrolled prospectively, with 31 3-part and 20 4-part displaced fractures (head displacement greater than 45°, tuberosity-head gap greater than 10mm, diaphyseal gap greater than 10mm). A Telegraph™ nail (FH Orthopedics, Heimsbrunn, France) was the fixation device used, introduced through a superolateral transdeltoid approach under fluoroscopic guidance. The assessment included Simple Shoulder Test, absolute Constant score, X-rays every 3 months and CT-scan at final evaluation. Twelve patients died and one was lost to follow-up. Immediate complications included secondary displacement in four patients.
RESULTS
There were no infections, no deltoid muscle or axillary nerve damage, and all the fractures united. After a mean follow-up of 24.1 months, malunion was observed in 29% of the remaining 38 patients and osteonecrosis in 32%. Both complications were more frequent and extensive in patients with 4-part fractures. The osteonecrosis area influenced the Constant score, which was 55.8 points when the area was less than 30%, 50.6 points between 30 and 50%, and 38 points when larger than 50%. Head malunion affected the Simple Shoulder Test and the Constant score.
CONCLUSION
Nailing may thus be recommended for 3-part fractures, because osteonecrosis is less frequent, more focused, and better tolerated in this sub-group. In contrast, antegrade nailing was not more beneficial than other internal fixation techniques for preventing osteonecrosis or head malunion in patients with 4-part fractures.
LEVEL OF EVIDENCE: Level IV: prospective study.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.