MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-012-1532-7

Медицинская библиотека · International orthopaedics · 2012

The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty.

Schmidutz Florian, Steinbrück Arnd, Wanke-Jellinek Lorenz, Pietschmann Matthias, Jansson Volkmar, Fottner Andreas

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Selection of the correct femoral stem size is crucial in total hip arthroplasty for an uncomplicated implantation and good initial stability. Pre-operative templating has been shown to be a valuable tool in predicting the correct implant size. For short-stem total hip arthroplasty (SHA), which recently is increasingly used, it is unknown if templating can be performed as reliable as conventional total hip arthroplasty (THA).

METHODS

A total of 100 hip arthroplasties, 50 with SHA and 50 with THA, were templated by four orthopaedic surgeons each. The surgeons had different levels of professional experience and performed a digital template of the acetabular and femoral component on the pre-operative radiographs. The results were compared with the truly inserted implant size.

RESULTS

For the femoral stems the average percentage of agreement (± 1 size) was 89.0 % in SHA and 88.5 % in THA. There was no significant difference among surgeons in the accuracy of templating the correct stem size and no significant difference between templating SHA and THA. For the acetabular component the average percentage of agreement (± 1 size) was 75.8 %. However, the more experienced surgeons showed a significant higher accuracy for templating the correct cup size than the less experienced surgeons.

CONCLUSION

Digital templating of SHA can predict the stem sizes as accurately as conventional THA. Therefore digital templating is also recommendable for SHA, as it helps to predict the implant size prior to surgery and thereby might help to avoid complications.

Для цитирования: Schmidutz Florian, Steinbrück Arnd, Wanke-Jellinek Lorenz, Pietschmann Matthias, Jansson Volkmar, Fottner Andreas. The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty.. International orthopaedics. 2012. DOI: 10.1007/s00264-012-1532-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.