DOI 10.1186/s12891-022-05956-9
Reoperation rate and implants' position variation features of displaced femoral neck fractures with sliding compression or length-stable fixation in young and middle-aged population.
Аннотация
INTRODUCTION
Sliding compression fixation and length-stable fixation are two basic internal fixation concepts in the treatment of displaced femoral neck fractures. In this study, we aimed to compare the reoperation rates for different methodologies of internal fixation for femoral neck fractures in young and middle-aged population.
MATERIALS AND
METHODS
This a retrospective study. A total of 215 patients with displaced femoral neck fractures treated with cannulated screw fixation were enrolled and divided into the sliding compression and length-stable groups according to the fixation pattern. The occurrence of and reason for revision surgery within one year were recorded. Forty-five patients with complete CT data (including CT scanning on the first postoperative day and at the last follow up) were selected from the total sample. A newly established computerized image processing method was used to evaluate variations in the spatial location of screws.
RESULTS
The reoperation rate was significantly higher in the length-stable group (23.8%) than in the sliding compression group (7.3%). The rate of revision surgery due to nonunion was also higher in the length-stable group (11.4%) than in the sliding compression group (1.8%). However, no significant difference was observed in terms of joint penetration or soft tissue irritation. The sliding compression group (6.58 ± 3.18 mm) showed higher femoral neck shortening than length-stable group (4.16 ± 3.65 mm). When analyzing the spatial variations, a significantly greater screw withdrawal distance was observed in the sliding compression group than in the length-stable group, but with a smaller rotation angle.
CONCLUSION
Length-stable internal fixation of displaced femoral neck fractures may lead to an increased reoperation rate in young and middle-aged population.
TRIAL REGISTRATION: Name of the registry: Chinese Clinical Trial Registry.
TRIAL REGISTRATION NUMBER: ChiCTR2000032327. Trial registration date: 2020-4-26.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.