Медицинская библиотека · BMC oral health · 2024

Post-BSSO condylar position stability: a comparison of miniplate and lag screw fixation.

Aliabadi Ehsan, Eskandari Fateme, Zanjani Milad, Babouei Moslem

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

This study was conceived to assess the postoperative stability of condylar position following fixation with miniplates and lag screws after bilateral sagittal split osteotomy (BSSO).

METHODS

This retrospective study included a cohort of 20 patients undergoing BSSO using the Obwegeser-Dal Pont modification. The bony segments were stabilized using either miniplates with two 2.0-mm monocortical screws per segment or three 2.0-mm bicortical lag screws along the mandible's superior border. Pre- and postoperative (7-day interval) spiral computed tomography scans were conducted to assess skeletal changes across both groups. Data analysis employed Wilcoxon signed-rank and Wilcoxon rank-sum tests (α = 0.05).

RESULTS

No statistically significant difference was observed between the pre-and postoperative condylar position parameters (P>0.05). However, the lag screw group showed a marginal significant increase in the left condyle's angulation (preoperative: 24.83 ± 6.37 vs. postoperative: 32.5 ± 4.93; P = 0.04). Changes in condylar height, length, and width were not statistically significant before and after BSSO in either groups (P>0.05). Nor was any statistically significant difference found between the miniplates and lag screws groups regarding condylar position parameters (P>0.05).

CONCLUSION

The results indicated that both lag screw and miniplate fixation methods can be effectively employed in BSSO procedures without impacting condylar position parameters. Thus, either fixation method can be chosen depending on factors such as the surgeon's preference and clinical outcomes.

Для цитирования: Aliabadi Ehsan, Eskandari Fateme, Zanjani Milad, Babouei Moslem. Post-BSSO condylar position stability: a comparison of miniplate and lag screw fixation.. BMC oral health. 2024. DOI: 10.1186/s12903-024-04499-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.