The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2022

Complications related to the access site after transaxillary implantation of a microaxial left ventricular assist device.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lewin Daniel, Nersesian Gaik, Lanmüller Pia, Schoenrath Felix, Falk Volkmar, Potapov Evgenij V, Ott Sascha

Аннотация

BACKGROUND: Impella 5.0 and 5.5 (summarized as Impella 5+) are microaxial, catheter-based left ventricular assist devices (LVAD) that are implanted via a vascular graft sutured to the axillary artery and provide blood flow of up to 5.5 liter/min. This study aims to investigate the incidence of long-term complications following circulatory support with Impella 5+.

METHODS: A single-center retrospective analysis of 203 consecutive adult patients treated between January 2017 and September 2021 with a surgically implanted Impella 5.0 or 5.5 via a vascular graft sutured to the axillary artery.

RESULTS: The median Impella support duration was 8 days. Of 203 patients, 78 (38.4%) died while on temporary mechanical circulatory support. Fifty-five (27.1%) were successfully weaned from Impella 5+ and 70 (34.5%) were bridged to a durable LVAD with a median follow-up time of 232 (IQR 68.5, 597) days after Impella 5+ explantation. In 119 of these patients, the Impella was explanted and the vascular graft was shortened, ligated, and pushed under the pectoralis muscle; in 6 patients early graft infection prompted complete graft removal during explantation. In addition, 13 patients (10.9%) developed a late-onset graft infection after a median of 86 days, requiring complete (n = 10) or partial (n = 2) explantation of the retained graft. In 1 patient, the graft infection was successfully treated by conservative therapy. Our analysis identified no specific risk factors for graft infections. Of the 203 patients, 5 (2.5%) developed a brachial plexus injury resulting in neurological dysfunction.

CONCLUSIONS: In 10.9% of patients, retaining the vascular graft was complicated by a late graft infection. Complete explantation of the graft prosthesis may decrease the infection rate, but may in turn increase the risk of brachial plexus injury. On the other hand, this method offers the possibility of bedside explantation.