MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10165-012-0618-9

Медицинская библиотека · Modern rheumatology · 2012

Clinical and radiographic evaluation of total hip arthroplasties using porous tantalum modular acetabular components: 5-year follow-up of clinical trial.

Nakashima Yasuharu, Mashima Naohiko, Imai Hiroshi, Mitsugi Naoto, Taki Naoya, Mochida Yuichi, Owan Ichiro, Arakaki Kaoru, Yamamoto Takuaki, Mawatari Taro, Motomura Goro, Ohishi Masanobu, Doi Toshio, Kanazawa Masayuki, Iwamoto Yukihide

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Porous tantalum is a biomaterial newly applied for artificial joints. We present here 5-years follow-up report of a multicenter clinical trial of total hip arthroplasties (THA) with porous tantalum modular acetabular component (modular PTC).

METHODS

Study participants received 82 hips in 79 cases, with 61.2 months follow-up on average. Age at operation was 60.9 years. Clinical results were evaluated using Merle d'Aubigne Postel score. Presence of implant loosening, periacetabular radiolucency, osteolysis, and gap filling were examined for radiographic results.

RESULTS

Merle d'Aubigne Postel score improved from 10.0 to 16.4 points. All PTC were radiographically stable, with no evidence of progressive radiolucencies. Average polyethylene wear rate was 0.004 mm/year, with no periacetabular osteolysis. Fifteen hips (18.3%) showed a gap >1 mm; however, all showed bone filling within 12 months. PTC with oversized reaming was significantly less likely to have a gap. No implant failure was noted related to modularity. Resulting survival rate of modular PTC was 100% at 5 years.

CONCLUSIONS

Modular PTC showed excellent results at 5-years of follow-up. Some hips showed periacetabular gaps, which were filled with bone within 1 year. Further follow-up was needed to determine long-term efficacy.

Для цитирования: Nakashima Yasuharu, Mashima Naohiko, Imai Hiroshi, Mitsugi Naoto, Taki Naoya, Mochida Yuichi, Owan Ichiro, Arakaki Kaoru, Yamamoto Takuaki, Mawatari Taro, Motomura Goro, Ohishi Masanobu, Doi Toshio, Kanazawa Masayuki, Iwamoto Yukihide. Clinical and radiographic evaluation of total hip arthroplasties using porous tantalum modular acetabular components: 5-year follow-up of clinical trial.. Modern rheumatology. 2012. DOI: 10.1007/s10165-012-0618-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.