MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00198-016-3804-3

Медицинская библиотека · Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2017

Opportunistic screening for osteoporosis by routine CT in Southern Europe.

Alacreu Elena, Moratal David, Arana Estanislao

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

UNLABELLED: Feasibility evaluation of early detection of osteoporosis in oncologic patients by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed for other clinical indications, by using dual-energy X-ray absorptiometry (DXA) as reference. Abdominal CT images can identify patients with osteoporosis BMD without additional radiation exposure or cost.

INTRODUCTION

The purpose of the study is to evaluate the feasibility of early detection of osteoporosis by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed in oncologic patients, comparing calibrated and uncalibrated measurements by using dual-energy X-ray absorptiometry (DXA) as reference. We also performed an external validation of a threshold of 160 Hounsfield units (HU), proposed as highly sensitive.

METHODS

Cohort comprised CT-DXA pairs within a 6-month period performed for any indication on 326 consecutive adults, aged 62.4 ± 12.38 years (mean ± standard deviation). CT attenuation of trabecular bone in HU was measured at the axial cross sections of L1, L2, L3, and L4 vertebrae. Vertebral compression fractures were assessed by sagittal reconstruction view. Diagnostic performance measures and the area under the receiver operator characteristic curve (AUC) for diagnosing osteoporosis were calculated.

RESULTS

BMD values were statistical significantly lower at any vertebral level from L1 to L4 for patients with osteoporosis defined by DXA (p < 0.001). Calibrated and uncalibrated BMD values were significantly correlated (R 2 = 0.833, p < 0.01). An uncalibrated L1 CT attenuation threshold of 160 HU was more than 90 % sensitive, and a threshold of 73 HU was more than 90 % specific for distinguishing osteoporosis BMD. Fifty-nine percent of patients with vertebral compression fracture had non-osteoporotic DXA T-scores.

CONCLUSIONS

Abdominal CT images obtained for other reasons can identify patients with osteoporosis BMD without additional radiation exposure or cost. Uncalibrated values at L1 can detect more osteoporosis patients with spinal compression fractures than DXA in oncologic patients.

Для цитирования: Alacreu Elena, Moratal David, Arana Estanislao. Opportunistic screening for osteoporosis by routine CT in Southern Europe.. Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA. 2017. DOI: 10.1007/s00198-016-3804-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.