Comparative clinical outcomes and radiological images of clavicle hook plate versus Scorpion Plate® for unstable distal clavicle fractures.
Аннотация
BACKGROUND
Although various surgical methods are available for unstable distal clavicle fractures, consensus remains lacking on the optimal technique. Therefore, the present retrospective study aimed to compare the clavicle hook plate and Scorpion Plate® in terms of clinical outcomes and radiological findings for unstable distal clavicle fractures.
METHODS
Fifty-seven patients with unstable distal clavicle fractures who underwent treatment using a clavicle hook plate (Group H; 28 patients) or Scorpion Plate® (Group S; 29 patients) were included in the present study. No patients received additional augmentation and all were followed-up for >1 year (mean follow-up, 28 months). Clinical outcomes were operation time, bleeding volume, complications, range of motion (ROM) at 6 months after surgery and final follow-up, and clinical scores (Constant-Murley score and University of California, Los Angeles (UCLA) shoulder score). Radiological outcomes assessed were coracoclavicular distance (CCD), difference in CCD between affected and non-affected sides (ΔCCD), and acromioclavicular subluxation ratio (%ACS) from plain X-rays. The χ2 test and Mann-Whitney U test were used to compare each outcome.
RESULTS
Complications were seen in 3 shoulders (10.7%) in Group H. ROM was significantly worse in Group H at 6 months postoperatively, but no significant differences between groups were evident at final follow-up. Moreover, no significant differences in clinical outcomes were seen between groups. In terms of radiological results, Group H showed greater improvement in CCD and ΔCCD than Group S. Further, %ACS was significantly worse in Group S.
CONCLUSIONS
The clavicle hook plate allows reconstruction of a more anatomical position than the Scorpion Plate®, but carries a greater risk of complications. Conversely, the Scorpion Plate® has a low risk of complications, but acromioclavicular subluxation remains. However, no significant differences in ROM or clinical outcomes were apparent at final follow-up.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.