MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jam.12876

Медицинская библиотека · Journal of applied microbiology · 2015

Identification of high-risk Listeria monocytogenes serotypes in lineage I (serotype 1/2a, 1/2c, 3a and 3c) using multiplex PCR.

Nho S W, Abdelhamed H, Reddy S, Karsi A, Lawrence M L

Оценочное исследованиеСтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

AIMS: Using molecular subtyping techniques, Listeria monocytogenes is divided into three major phylogenetic lineages, and a multiplex PCR method can differentiate five L. monocytogenes subgroups: 1/2a-3a, 1/2c-3c, 1/2b-3b-7, 4b-4d-4e and 4a-4c. In this study, we conducted genome comparisons and evaluated serotype-associated genes for their utility as a multiplex PCR-based method for distinguishing high-risk serotypes 1/2a and 1/2c in lineage I from low-risk serotypes 3a and 3c.

METHODS AND

RESULTS

Primer sets were developed that are specific for serotype 1/2c (LMOSLCC2372_0308) and serotype 3a (LMLG_0742). These primers were then tested in a multiplex format with primers specific for serotype 1/2a (flaA) to separate serotypes 1/2a, 1/2c, 3a and 3c using 25 strains of lineage I L. monocytogenes.

CONCLUSIONS

Here, for the first time, we report primers specific for L. monocytogenes serotype 1/2c and serotype 3a, and we demonstrate a multiplex PCR method for separating the four serotypes of lineage I L. monocytogenes.

SIGNIFICANCE AND IMPACT OF THE STUDY: The described multiplex PCR assay consistently showed successful separation of 1/2a and 1/2c strains from 3a and 3c strains. PCR is routinely performed in many diagnostic and epidemiologic investigations for L. monocytogenes, and these primers should increase the feasibility and accessibility of L. monocytogenes serotyping.

Для цитирования: Nho S W, Abdelhamed H, Reddy S, Karsi A, Lawrence M L. Identification of high-risk Listeria monocytogenes serotypes in lineage I (serotype 1/2a, 1/2c, 3a and 3c) using multiplex PCR.. Journal of applied microbiology. 2015. DOI: 10.1111/jam.12876.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.