Does Patient-Specific Instrumentation Have a Higher Rate of Early Osteolysis Than Standard Referencing Techniques in Total Ankle Arthroplasty? A Radiographic Analysis.

Escudero Mario I, Symes Michael, Bemenderfer Thomas Bradford, Barahona Maximiliano, Anderson Robert, Davis Hodges, Wing Kevin J, Penner Murray J

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

Introduction

Patient-specific instrumentation (PSI) has been developed for total ankle arthroplasty (TAA), with proven benefits. One concern regarding PSI is the need for more soft tissue dissection in order to accurately position the PSI guides, which has the theoretical disadvantage of increased osteolysis. The purpose of our study is to compare the incidence and magnitude of osteolysis for the INFINITY Total Ankle System between PSI and standard referencing (SR) techniques.

Methods

Sixty-seven patients who underwent primary TAA using Prophecy (PSI) or SR technique between 2013 and 2015 were reviewed in a retrospective observational study. Osteolysis was assessed on radiographs at 2 years. The incidence was calculated by binomial distribution. The number of zones compromised and the magnitude of osteolysis was calculated using the median as a summary statistic and interquartile range as dispersion statistic. Fisher exact test was used to compare both groups, then a regression model was estimated to calculate the odds ratio for osteolysis.

Results

Of the 67 TAAs, 51 were in the PSI group and 16 in the SR group. In the PSI group the incidence, number of compromised zones (CZ), and magnitude was 41% (25%-59%), 1 [1-2], and 2 [2-3], respectively. In the SR group these were 36% (13%-65%), 3 [2-3], and 3 [2-4], respectively. No significant differences were found (P = .46, P = .12, P = .33). A slightly higher risk of osteolysis was found in the PSI group (odds ratio = 1.33 [0.36-4.83]) (P = .46). The majority of lesions were in 1 zone with size of 2 to 5 mm (63% for all cohort, 64% PSI, 60% SR). Two cases underwent revision for aseptic loosening, 1 in the SR group and 1 in the PSI group.

Conclusion

According to our data, there is no significant difference between PSI and SR in terms of risk, incidence, size and magnitude of osteolysis in the INFINITY Total Ankle System at 2 years. Levels of Evidence: Therapeutic, Level III, Retrospective cohort study.

Для цитирования: Escudero Mario I, Symes Michael, Bemenderfer Thomas Bradford, Barahona Maximiliano, Anderson Robert, Davis Hodges, Wing Kevin J, Penner Murray J. Does Patient-Specific Instrumentation Have a Higher Rate of Early Osteolysis Than Standard Referencing Techniques in Total Ankle Arthroplasty? A Radiographic Analysis.. Foot & ankle specialist. 2019. DOI: 10.1177/1938640019828069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.