MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s001980070108

Медицинская библиотека · Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2000

Discrimination of proximal hip fracture by quantitative ultrasound measurement at the radius.

Weiss M, Ben-Shlomo A, Hagag P, Ish-Shalom S

СтатьяПеревод в очереди

Аннотация

Osteoporosis is a disease that culminates in fragility fractures and, therefore, imposes major burden on the health economy. In dealing with this worldwide condition, it is prudent to use a reliable, inexpensive, portable diagnostic means that does not use ionizing radiation and is capable of measuring bone properties at several sites. Recently, a quantitative ultrasound device (Omnisense) that measures speed of sound (SOS) at multiple skeletal sites was introduced. The Omnisense combines the 'axial transmission' mode and the critical angle concept. Preliminary reports suggested that of the different skeletal sites measured by this device, the distal third of the radius is the preferred measurement site for osteoporosis. In this cross-sectional study, SOS was determined at the radius using Omnisense in 50 hip-fractured elderly women (group F, age 76.1 +/- 6.0 years), 130 elderly controls (group NF, age 71.5 +/- 5.2 years) and 185 young healthy controls (group YH, age 40.6 +/- 3.0 years). Actual SOS was significantly lower in group F compared with group NF (p = 0.0001). Whereas SOS T-scores calculated for each woman and stratified into age subgroups within each of the study groups indicate decline from -2.22 to -3.56 in group F and from -1.56 to -3.17 in group NF, there was an increase from -0.02 to 0.03 in group YH. Age- and BMI-adjusted logistic regression for hip fracture discrimination indicated an area under the receiver operating characteristic curve for hip fracture of 0.79 (95% CI, 0.73-0.86; p = 0.005) and an odds ratio of 1.92 (95% CI, 1.22-3.02; p = 0.005). We conclude that SOS measured at the radius by Omnisense discriminates subjects with hip fracture. from controls. Prospective studies are needed to support the role of Omnisense in assessing the risk of hip fracture.

Для цитирования: Weiss M, Ben-Shlomo A, Hagag P, Ish-Shalom S. Discrimination of proximal hip fracture by quantitative ultrasound measurement at the radius.. Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA. 2000. DOI: 10.1007/s001980070108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.