Perkel David J, Giardina Christopher K, Goldwyn Joshua H, Arenberg Julie G

СтатьяПеревод в очереди

Аннотация

PURPOSE: Cochlear implants (CI) are a highly successful neural prosthesis that can restore hearing in individuals with sensorineural hearing loss. However, the extent of hearing restoration varies widely. Two major factors likely contribute to poor performance: (1) the distances between electrodes and surviving spiral ganglion neurons and (2) the density of those neurons. Reprogramming the CI at a poor electrode-neuron interface, using focused tripolar stimulation or remapping the electrodes, would benefit from understanding the cause of the poor interface.

METHODS

We used a cochlear model with simplified geometry and neuronal composition to investigate how the interface affects stimulation thresholds. We then inverted the model to infer electrode distance and neuronal density from monopolar and tripolar threshold values obtained behaviorally. We validated this inverted model for known scenarios of electrode distance and neuronal density. Finally, we assessed the model using data from 18 CI users whose electrode distances were measured from CT imaging.

RESULTS

The inverted model accurately inferred electrode distance and neuronal density for known scenarios. It also reliably reproduced behavioral monopolar and tripolar threshold profiles for CI users, with mean prediction errors within 1 dB for 17/18 subjects. Fits of electrode distance were more variable; accuracy depended on the assumed value of temporal bone resistivity. Twelve subjects had minimum distance error (0.31 mm) using low resistivity (70 Ω-cm) while the others had better fits (0.30 mm) with higher resistivity (250 Ω-cm).

CONCLUSION

This inverted model shows promise as a simple, practical tool to better assess and understand the electrode-neuron interface.

Для цитирования: Perkel David J, Giardina Christopher K, Goldwyn Joshua H, Arenberg Julie G. Model-Based Inference of Electrode Distance and Neuronal Density from Measured Detection Thresholds in Cochlear Implant Listeners.. Journal of the Association for Research in Otolaryngology : JARO. 2025. DOI: 10.1007/s10162-025-00978-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.