BACKGROUND

Ceramic bearings in total hip arthroplasty (THA) have been introduced in clinical practice to minimize the problem of polyethylene particle-induced osteolysis. The aim of the study is to report the results of 68 consecutive alumina-on-alumina THAs done in 61 patients for avascular necrosis (AVN) of the femoral head.

MATERIALS AND

METHODS

In all implants a press-fit cup was used; it was combined with a 32-mm alumina head and with titanium-alloy stems. The mean age at surgery was 50 years. At an average follow-up of 13 years two hips have been revised, one for periprosthetic infection and one for excessive abduction of the cup.

RESULTS

No revision for aseptic loosening is recorded; one anatomical cementless femoral stem had radiological evidence of definite aseptic loosening. No dislocations occurred, and no osteolysis was observed.

CONCLUSIONS

The results support the application of alumina-alumina THA for long-lasting replacements.

Для цитирования: Solarino Giuseppe, Piazzolla Andrea, Notarnicola Angela, Moretti Lorenzo, Tafuri Silvio, De Giorgi Silvana, Moretti Biagio. Long-term results of 32-mm alumina-on-alumina THA for avascular necrosis of the femoral head.. Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology. 2012. DOI: 10.1007/s10195-011-0174-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.