MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.bsd.0000211243.44706.2b

Медицинская библиотека · Journal of spinal disorders & techniques · 2007

PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis--in augmentation with a pedicle screw.

Okuyama Koichiro, Kido Tadato, Unoki Eiki, Chiba Mitsuho

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the validity of posterior lumbar interbody fusion (PLIF) using a titanium cage filled with excised facet joint bone and a pedicle screw for degenerative spondylolisthesis.

METHODS

PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw was performed in 28 consecutive patients (men 10, women 18). The mean age of the patients was 60 years (range, 52 to 75 y) at the time of surgery. The mean follow-up period was 2.3 years (range, 2.0 to 4.5 y). The operation was done at L3/4 in 5, L4/5 in 20, and L3/4/5 in 3 patients. The mean operative bleeding was 318+/-151 g (mean+/-standard deviation), and the mean operative time was 3.34+/-0.57 hours per fixed segment. Clinical outcome was assessed by Denis' Pain and Work scale. Radiologic assessment was done using Boxell's method. Fusion outcome was assessed using an established criteria.

RESULTS

On Pain scale, 20 and 8 patients were rated P4 and P5 before surgery, and 11, 12, 2, 2, and 1 patients were rated P1, P2, P3, P4, and P5 at final follow-up, respectively. On Work scale (for only physical labors), 12 and 9 patients were rated W4 and W5, before surgery, and 12, 5, 1, and 3 patients were rated W1, W2, W3 and W5 at final follow-up, respectively. There was significant difference in clinical outcome (P<0.01, Wilcoxon singled-rank test) The mean %Slip and Slip Angle was 17.9+/-8.1% and 3.9+/-5.8 degrees before surgery. The mean % Slip and Slip Angle was 5.4+/-4.4% and -2.0+/-4.8 degrees at final follow-up. There was a significant difference between the values (P<0.01, paired t test). "Union" and "probable union" was determined in 29 (93.5%) and 2 (6.5%) of 31 operated segments at 2.3 years (range, 2.0 to 4.5 y), postoperatively.

CONCLUSIONS

PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw provided a satisfactory clinical outcome and an excellent union rate without harvesting and grafting the autologous iliac bone.

Для цитирования: Okuyama Koichiro, Kido Tadato, Unoki Eiki, Chiba Mitsuho. PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis--in augmentation with a pedicle screw.. Journal of spinal disorders & techniques. 2007. DOI: 10.1097/01.bsd.0000211243.44706.2b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.